FALL FURNACE Clean & Inspect Burners Clean & Inspect Heat Exchanger Test Gas Shut-Off Valve Clean & Check Pressure Tubes Clean Furnace Cabinet Inspect Blower Wheel Inspect & Clean Igniter Check Thermostat Inspect Vent Pipes Inspect Combustion Air Pipes Clean & Check Condensate Plumbing Inspect Electrical Connections Clean Flame Sensor Measure & Record Temperature Rise Measure & Record Gas Valve Measure & Record Gas Pressure Perform Carbon Monoxide Check Measure & Record Capacitor Rating Measure & Record Blower Motor Amps Check & Clean Or Replace Air Filter Inspect & Check Ducts For Leakage Inspect & Check For Proper Fuse Size
SPRING AIR CONDITIONER Clean & Inspect Condenser Coil Clean & Inspect Evaporator Coil Inspect Blower Wheel Clean & Test Safety Controls Check Unit Disconnect Check & Inspect Contractor Inspect Airflow Clean & Check Condensate Plumbing Inspect Electrical Connections Leak Check & Inspect Refrigerant Inspect Motor Bearing Check Condenser Blade Balance Measure & Record Capacitor Rating Measure & Record Compressor Amps Measure & Record Condition Motor Amps Measure & Record Super Heat/Sub-Cool Measure & Record Temp Split Measure & Record Line Voltage Measure & Record Head Unit Pressure Measure & Record Suction Pressure Inspect & Clean Or Replace Belt Check & Clean Or Replace Air Filter Check & Inspect Circuit Breaker Sizing Inspect & Check Ducts For LeakageAdditional Benefits